welcome,guest

Meind UPS Inverter 2000W to Make UPS Power System with Battery DC to AC/AC to DC

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-09 11:20

  • Browse the number:

    206

Send an inquiries

Company Profile

Shenzhen Meind Technology Co., Ltd

By certification [File Integrity]

Contact: meind(Ms.)  

Telephone:

Area: Beijing

Address: Beijing

Website: http://meind.qdaokai.com/

New Products
Product details
Model Number: ZUPS-2KW Brand Name: Meind Key Specifications/Special Features: UPS inverter 2000W + pure sine wave inverter + built in battery chargerMND-ZUPS2000WMeind UPS function/auto-switch: when main power is off, inverter will auto-switch on and converter battery power to AC220V, when main power is on, inverter will auto change to charging, charging battery.Specifications:1) Input voltages: DC12V(10—15V)2) Output voltage: AC220V3) Continuous power output: 2000W4) Surge power capacity: 4000W5) Output wave form: Pure sine wave
6) Frequency output: 50Hz, (60Hz) ±4%
7) Availability power: ≥90.5%
8) Low voltage range: <DC9.6V
9) High voltage range: >DC14.8V
10) No load current: ≤0.4A
11) Soft-switch function: Yes
12) Short-circuit protection: Yes
13) Reverse protection: Yes ( +/ - )
14) Over-load protection: >2000W
15) High-temperature protection: >70℃ will turn off, and re-boot < 50℃
16) High-voltage protection: DC16V±1V
17) Low-voltage protection: DC10.5V±0.5V
18) Auto reboot function: Yes
19) Fuse: Built-in 8X30A
20) Cooling fan: Yes (Automatic: when temperature >48℃, will auto-start to cooling, and after <40℃ will off)
21) USB port output current: No USB port.
22) Charging function: Yes (Charging specification: Constant voltage and trickle current charge when the battery voltage ≤14.4V, after ≥13.8V floating charge.)
23) Input when charging: AC 110V-240V
24) Output of charging: DC 14.4V
25) Charging current: about 10A
26) The inverter will alarm and cut off when the battery is full of power。
27)Size: 420*190*71mm
28) UPS function: when main power is off, inverter will auto-switch on and converter battery power to AC220V, when main power is on, inverter will auto change to charging, to charge battery.

Firstly, connect battery (12V inverter need 12V battery, 24V inverter need 24V battery) to inverter correctly—battery “+” to inverter“+”, battery “-” to inverter “-”, this inverter have reverse protection.
Then,please connect AC cable to inverter’s AC input port from your main power
Thirdly, connect your appliance or device to inverter’s AC output socket
At last, put “Main Switch” in “ON”, now all system set up and working.
Shipping Information:
  • FOB Port: Shenzhen
  • Lead Time: 3 - 7 days
Main Export Markets:
  • Asia